A “Large-N” Content Uniformity Process Analytical Technology (PAT) Method for Phenytoin Sodium Tablets

Pallavi Pawar, Sameer Talwar, Dheerja Reddy, Chandra Kanth Bandi, Huiquan Wu, Koushik Sowrirajan, Rick Friedman, German Drazer, James K. Drennen, Fernando Muzzio

Research output: Contribution to journalArticle

Abstract

Accurate assessment of tablet content uniformity is critical for narrow therapeutic index drugs such as phenytoin sodium. This work presents a near-infrared (NIR)-based analytical method for rapid prediction of content uniformity based on a large number of phenytoin sodium formulation tablets. Calibration tablets were generated through an integrated experimental design by varying formulation and process parameters, and scale of manufacturing. A partial least squares model for individual tablet content was developed based on tablet NIR spectra. The tablet content was obtained from a modified United States Pharmacopeia phenytoin sodium high-performance liquid chromatography assay method. The partial least squares model with 4 latent variables explained 92% of the composition variability and yielded a root mean square error of prediction of 0.48% w/w. The resultant NIR model successfully assayed the composition of tablets manufactured at the pilot scale. For one such batch, bootstrapping was applied to calculate the confidence intervals on the mean, acceptance value, and relative SD for different sample sizes, n = 10, 30, and 100. As the bootstrap sample size increased, the confidence interval on the mean, acceptance value, and relative SD became narrower and symmetric. Such a ‘large N’ NIR-based process analytical technology method can increase reliability of quality assessments in solid dosage manufacturing.

LanguageEnglish (US)
Pages494-505
Number of pages12
JournalJournal of Pharmaceutical Sciences
Volume108
Issue number1
DOIs
StatePublished - Jan 1 2019

Fingerprint

Phenytoin
Tablets
Technology
Least-Squares Analysis
Sample Size
Confidence Intervals
Pharmacopoeias
Calibration
Research Design
High Pressure Liquid Chromatography
Pharmaceutical Preparations

Cite this

Pawar, Pallavi ; Talwar, Sameer ; Reddy, Dheerja ; Bandi, Chandra Kanth ; Wu, Huiquan ; Sowrirajan, Koushik ; Friedman, Rick ; Drazer, German ; Drennen, James K. ; Muzzio, Fernando. / A “Large-N” Content Uniformity Process Analytical Technology (PAT) Method for Phenytoin Sodium Tablets. In: Journal of Pharmaceutical Sciences. 2019 ; Vol. 108, No. 1. pp. 494-505.
@article{555906ca8fcd4465a89708adfa3206fe,
title = "A “Large-N” Content Uniformity Process Analytical Technology (PAT) Method for Phenytoin Sodium Tablets",
abstract = "Accurate assessment of tablet content uniformity is critical for narrow therapeutic index drugs such as phenytoin sodium. This work presents a near-infrared (NIR)-based analytical method for rapid prediction of content uniformity based on a large number of phenytoin sodium formulation tablets. Calibration tablets were generated through an integrated experimental design by varying formulation and process parameters, and scale of manufacturing. A partial least squares model for individual tablet content was developed based on tablet NIR spectra. The tablet content was obtained from a modified United States Pharmacopeia phenytoin sodium high-performance liquid chromatography assay method. The partial least squares model with 4 latent variables explained 92{\%} of the composition variability and yielded a root mean square error of prediction of 0.48{\%} w/w. The resultant NIR model successfully assayed the composition of tablets manufactured at the pilot scale. For one such batch, bootstrapping was applied to calculate the confidence intervals on the mean, acceptance value, and relative SD for different sample sizes, n = 10, 30, and 100. As the bootstrap sample size increased, the confidence interval on the mean, acceptance value, and relative SD became narrower and symmetric. Such a ‘large N’ NIR-based process analytical technology method can increase reliability of quality assessments in solid dosage manufacturing.",
author = "Pallavi Pawar and Sameer Talwar and Dheerja Reddy and Bandi, {Chandra Kanth} and Huiquan Wu and Koushik Sowrirajan and Rick Friedman and German Drazer and Drennen, {James K.} and Fernando Muzzio",
year = "2019",
month = "1",
day = "1",
doi = "https://doi.org/10.1016/j.xphs.2018.06.031",
language = "English (US)",
volume = "108",
pages = "494--505",
journal = "Journal of Pharmaceutical Sciences",
issn = "0022-3549",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

A “Large-N” Content Uniformity Process Analytical Technology (PAT) Method for Phenytoin Sodium Tablets. / Pawar, Pallavi; Talwar, Sameer; Reddy, Dheerja; Bandi, Chandra Kanth; Wu, Huiquan; Sowrirajan, Koushik; Friedman, Rick; Drazer, German; Drennen, James K.; Muzzio, Fernando.

In: Journal of Pharmaceutical Sciences, Vol. 108, No. 1, 01.01.2019, p. 494-505.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A “Large-N” Content Uniformity Process Analytical Technology (PAT) Method for Phenytoin Sodium Tablets

AU - Pawar, Pallavi

AU - Talwar, Sameer

AU - Reddy, Dheerja

AU - Bandi, Chandra Kanth

AU - Wu, Huiquan

AU - Sowrirajan, Koushik

AU - Friedman, Rick

AU - Drazer, German

AU - Drennen, James K.

AU - Muzzio, Fernando

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Accurate assessment of tablet content uniformity is critical for narrow therapeutic index drugs such as phenytoin sodium. This work presents a near-infrared (NIR)-based analytical method for rapid prediction of content uniformity based on a large number of phenytoin sodium formulation tablets. Calibration tablets were generated through an integrated experimental design by varying formulation and process parameters, and scale of manufacturing. A partial least squares model for individual tablet content was developed based on tablet NIR spectra. The tablet content was obtained from a modified United States Pharmacopeia phenytoin sodium high-performance liquid chromatography assay method. The partial least squares model with 4 latent variables explained 92% of the composition variability and yielded a root mean square error of prediction of 0.48% w/w. The resultant NIR model successfully assayed the composition of tablets manufactured at the pilot scale. For one such batch, bootstrapping was applied to calculate the confidence intervals on the mean, acceptance value, and relative SD for different sample sizes, n = 10, 30, and 100. As the bootstrap sample size increased, the confidence interval on the mean, acceptance value, and relative SD became narrower and symmetric. Such a ‘large N’ NIR-based process analytical technology method can increase reliability of quality assessments in solid dosage manufacturing.

AB - Accurate assessment of tablet content uniformity is critical for narrow therapeutic index drugs such as phenytoin sodium. This work presents a near-infrared (NIR)-based analytical method for rapid prediction of content uniformity based on a large number of phenytoin sodium formulation tablets. Calibration tablets were generated through an integrated experimental design by varying formulation and process parameters, and scale of manufacturing. A partial least squares model for individual tablet content was developed based on tablet NIR spectra. The tablet content was obtained from a modified United States Pharmacopeia phenytoin sodium high-performance liquid chromatography assay method. The partial least squares model with 4 latent variables explained 92% of the composition variability and yielded a root mean square error of prediction of 0.48% w/w. The resultant NIR model successfully assayed the composition of tablets manufactured at the pilot scale. For one such batch, bootstrapping was applied to calculate the confidence intervals on the mean, acceptance value, and relative SD for different sample sizes, n = 10, 30, and 100. As the bootstrap sample size increased, the confidence interval on the mean, acceptance value, and relative SD became narrower and symmetric. Such a ‘large N’ NIR-based process analytical technology method can increase reliability of quality assessments in solid dosage manufacturing.

UR - http://www.scopus.com/inward/record.url?scp=85051401256&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85051401256&partnerID=8YFLogxK

U2 - https://doi.org/10.1016/j.xphs.2018.06.031

DO - https://doi.org/10.1016/j.xphs.2018.06.031

M3 - Article

VL - 108

SP - 494

EP - 505

JO - Journal of Pharmaceutical Sciences

T2 - Journal of Pharmaceutical Sciences

JF - Journal of Pharmaceutical Sciences

SN - 0022-3549

IS - 1

ER -