Abstract
We prospectively compared and correlated interictal spikes recorded with simulataneous surface, sphenoidal, depth and subdural electrodes in 21 patients. Although the amplitude of sphenoidal spikes was often larger than that of surface spikes in patients with mesial basal temporal ictal and interictal foci, only 1 patient had exclusively sphenoidal spikes. Spikes with maximal amplitude at the sphenoidal electrode arose from mesial temporal, temporal neocortical and orbital frontal foci. An inferior vertical temporal dipole (hippocampal positive and inferior temporal neocortex negative) was associated with surface and sphenoidal spikes.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 23-29 |
| Number of pages | 7 |
| Journal | Electroencephalography and Clinical Neurophysiology |
| Volume | 82 |
| Issue number | 1 |
| DOIs | |
| State | Published - Jan 1992 |
ASJC Scopus subject areas
- General Neuroscience
- Clinical Neurology
Keywords
- Epilepsy
- Interictal spiking
- Intracranial recording
- Sphenoidal electrodes
Fingerprint
Dive into the research topics of 'Comparison and correlation of surface and sphenoidal electrodes with simultaneous intracranial recording: an interictal study'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver