Abstract
The results of an experimental investigation on the flexural behavior of steel fiber reinforced concrete (SRC) are reported in this paper. Even though a number of investigations had been carried out in this area, comprehensive results on the toughness behavior are not available, especially for FRC reinforced with deformed fibers. In addition, a relatively new procedure was used to measure the deflections accurately. The accurate measurement of deflections lead to significant changes in the toughness values. The variables investigated were: fiber type, length, and volume fraction; and matrix composition. Three fiber types, three fiber lengths, four fiber volume fractions, and four matrix compositions were evaluated. The results indicate that fiber content in the range of 50 to 100 lb/yd3 (30 to 60kg/m3) provide excellent ductility for normal strength concrete. The fiber content has to be increased to about 150 lb/yd3 (90kg/m3) for high-strength concrete. Hooked-end fiber geometry provides better results than corrugated and deformed-end geometry. Fiber length, in the range of 1.18 to 2.36 in. (30 to 60 mm) does not have a significant effect on toughness for hooked-end fibers. Ductile behavior can be obtained using 200 lb/yd3 (120kg/m3) of fibers, even for concrete containing 20 percent silica fume by weight of cement. Some of the toughness index values specified in ASTM are not sensitive enough to differentiate any of the variables investigated in this study.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 541-546 |
| Number of pages | 6 |
| Journal | ACI Materials Journal |
| Volume | 89 |
| Issue number | 6 |
| State | Published - Nov 1992 |
ASJC Scopus subject areas
- Civil and Structural Engineering
- Building and Construction
- General Materials Science
Fingerprint
Dive into the research topics of 'Flexural toughness of steel fiber reinforced concrete'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver