Skip to main navigation Skip to search Skip to main content

Prior hematologic conditions carry a high morbidity and mortality in patients supported with continuous-flow left ventricular assist devices

  • Justin Fried
  • , Allison P. Levin
  • , Kanika M. Mody
  • , Arthur R. Garan
  • , Melana Yuzefpolsakaya
  • , Hiroo Takayama
  • , David L. Diuguid
  • , Yoshifumi Naka
  • , Ulrich Jorde
  • , Nir Uriel

Research output: Contribution to journal › Article › peer-review

Abstract

Background: Mechanical support leads to an increased risk of both bleeding and thrombotic events, but little is known about the risk of device support in patients with a baseline predisposition to these events. The aim of this study was to examine outcomes among patients with baseline hematologic conditions who underwent continuous-flow LVAD implantation (CF-LVAD).

Methods: We retrospectively reviewed records of 286 patients who underwent CF-LVAD implantation at the Columbia University Medical Center between April 2008 and December 2013. Patients diagnosed with the following hematologic conditions were enrolled: idiopathic thrombocytopenic purpura (ITP); Factor V Leiden; elevated Factor VIII; heparin-induced thrombocytopenia (HIT); or undefined hypercoagulable state.

Conclusions: Patients with a history of prior hematologic conditions are at high risk for bleeding, thrombotic and neurologic events during device support, leading to early mortality. This case series questions the benefit of CF-LVAD in these patients and the appropriate management with regard to anti- coagulation. Further studies on the outcomes of these patients are warranted.

Results: Of the 286 CF-LVAD patients implanted during the study period, 12 were considered to have a significant hematologic condition predisposing them to either bleeding or thrombotic events. The study included 5 patients with ITP, 1 with Factor V Leiden, 1 with elevated Factor VIII, 2 with HIT and 3 patients with undefined hypercoagulable state. Patients were supported for a total of 168.46 months, with a median of 10.76 months (IQR 4.78 to 21.36 months). There was a high frequency of thrombotic (0.57 event per patient-year), neurologic (0.36 event per patient-year) and bleeding (0.64 event per patient-year). Actuarial survival rates at 6 and 12 months were 81.8%, but fell to 49% at 2 years.

Original languageEnglish
Pages (from-to)1119-1125
Number of pages7
JournalJournal of Heart and Lung Transplantation
Volume33
Issue number11
DOIs
StatePublished - Nov 1 2014

ASJC Scopus subject areas

  • Surgery
  • Pulmonary and Respiratory Medicine
  • Cardiology and Cardiovascular Medicine
  • Transplantation

Keywords

  • ITP
  • LVAD
  • bleeding
  • hematological conditions
  • hypercoagulable
  • mechanical circulatory support
  • patient selection
  • thrombosis

Fingerprint

Dive into the research topics of 'Prior hematologic conditions carry a high morbidity and mortality in patients supported with continuous-flow left ventricular assist devices'. Together they form a unique fingerprint.

Cite this