TY - GEN
T1 - Sediment monitoring bias by autosampler in comparison with whole volume sampling for parking lot runoff
AU - Fowler, George D.
AU - Roseen, Robert M.
AU - Ballestero, Thomas P.
AU - Guo, Qizhong
AU - Houle, James
PY - 2009
Y1 - 2009
N2 - A field study was conducted to assess biases of suspended sediment concentration (SSC) analyses (ASTM standard D 3977-97) performed on discrete samples obtained by auto-sampler in comparison with actual sediment concentrations from whole volume sampling. Research results indicate that the biases attributed to monitoring of sediment event mean concentration (EMC) and particle size distribution (PSD) in parking lot runoff by automated samplers (non-isokinetic) can be insignificant. Large volume samples (∼15,000 L) of the full pipe cross-section were taken from a stormwater sewer system for eighteen storm events over two years to monitor for EMCs and PSDs. Concurrently, flow weighted grab samples were obtained by automatic samplers throughout the entire large volume sampling period. Thus characteristics of sediments were compared from a "whole storm" sample with that of "sub- samples" obtained by an autosampler using non-isokinetic sampling. SSCs and particle size distributions were compared for the two respective field sampling methods. The two methods showed a strong correlation for median sediment EMCs (R2 =.9801, n=18). Biases to particle size distributions were found to be largely confined to the large particles (>160 um) representing less than 25 of the load by mass. Moreover, sediment particles captured by the whole volume sampling and autosampler were not significantly different (α=0.05) for D50's=0.067=and0.047 microns respectively (particle size at which 50 of the sample mass is less).
AB - A field study was conducted to assess biases of suspended sediment concentration (SSC) analyses (ASTM standard D 3977-97) performed on discrete samples obtained by auto-sampler in comparison with actual sediment concentrations from whole volume sampling. Research results indicate that the biases attributed to monitoring of sediment event mean concentration (EMC) and particle size distribution (PSD) in parking lot runoff by automated samplers (non-isokinetic) can be insignificant. Large volume samples (∼15,000 L) of the full pipe cross-section were taken from a stormwater sewer system for eighteen storm events over two years to monitor for EMCs and PSDs. Concurrently, flow weighted grab samples were obtained by automatic samplers throughout the entire large volume sampling period. Thus characteristics of sediments were compared from a "whole storm" sample with that of "sub- samples" obtained by an autosampler using non-isokinetic sampling. SSCs and particle size distributions were compared for the two respective field sampling methods. The two methods showed a strong correlation for median sediment EMCs (R2 =.9801, n=18). Biases to particle size distributions were found to be largely confined to the large particles (>160 um) representing less than 25 of the load by mass. Moreover, sediment particles captured by the whole volume sampling and autosampler were not significantly different (α=0.05) for D50's=0.067=and0.047 microns respectively (particle size at which 50 of the sample mass is less).
UR - https://www.scopus.com/pages/publications/70350180229
UR - https://www.scopus.com/pages/publications/70350180229#tab=citedBy
U2 - 10.1061/41036(342)150
DO - 10.1061/41036(342)150
M3 - Conference contribution
SN - 9780784410363
T3 - Proceedings of World Environmental and Water Resources Congress 2009 - World Environmental and Water Resources Congress 2009: Great Rivers
SP - 1514
EP - 1522
BT - Proceedings of World Environmental and Water Resources Congress 2009 - World Environmental and Water Resources Congress 2009
T2 - World Environmental and Water Resources Congress 2009: Great Rivers
Y2 - 17 May 2009 through 21 May 2009
ER -