TY - JOUR
T1 - Some aspects of chemical ionization mass spectroscopy using ammonia as reagent gas
T2 - A valuable technique for biomedical and natural products studies
AU - Bose, Ajay K.
AU - Fujiwara, Hideji
AU - Pramanik, Birendra N.
AU - Lazaro, Eric
AU - Spillert, Charles R.
N1 - Funding Information: The authors are grateful to the U. S Public Health Service (SROI AM 17921-02) New York Cardiac Center, Stevens Institute of Technology, and New Jersey Medical School for financial support of this research. The Biospect mass spectrometer (manufactured by Scientific Research Instruments of Baltimore, Baltimore, Md.) used in this study was acquired with the help of a generous grant from Schering Foundation. The authors wish to thank Dr. A. Yergey for valuable technical advice and Ms. Anne Attridge, Mr. George Barasch, Dean E. Hirschberg, and Provost L. Z. Pollara for their interest and support.
PY - 1978/8/15
Y1 - 1978/8/15
N2 - The use of ammonia as reagent gas increases considerably the utility of chemical ionization mass spectroscopic (ci-ms) analysis: compounds of biological interest, such as steroid hormones, bile acids, prostaglandins, phospholipids, alkaloids, antibiotics, etc., display strong pseudomolecular ions (mostly M+ + 18). The need for derivatization and/or chromatographic purification of many types of compounds is sharply reduced. Ammonium carbonate or 15NH4Cl can be introduced into the direct probe for obtaining satisfactory ci-ms(NH3) spectra. Bile salts and some bile acid conjugates can be studied without derivatization. Potassium penicillanate gives a strong peak corresponding to the free acid + NH4+. Deproteinized blood samples provide a detailed picture of individual components, such as triglycerides, lysolecithins, cholesterol esters, etc. Frag-mentation patterns for structural information can be generated by adding argon to ammonia. One shortcoming of the ci-ms(NH3) method is the progressive replacement of halogen with hydrogen.
AB - The use of ammonia as reagent gas increases considerably the utility of chemical ionization mass spectroscopic (ci-ms) analysis: compounds of biological interest, such as steroid hormones, bile acids, prostaglandins, phospholipids, alkaloids, antibiotics, etc., display strong pseudomolecular ions (mostly M+ + 18). The need for derivatization and/or chromatographic purification of many types of compounds is sharply reduced. Ammonium carbonate or 15NH4Cl can be introduced into the direct probe for obtaining satisfactory ci-ms(NH3) spectra. Bile salts and some bile acid conjugates can be studied without derivatization. Potassium penicillanate gives a strong peak corresponding to the free acid + NH4+. Deproteinized blood samples provide a detailed picture of individual components, such as triglycerides, lysolecithins, cholesterol esters, etc. Frag-mentation patterns for structural information can be generated by adding argon to ammonia. One shortcoming of the ci-ms(NH3) method is the progressive replacement of halogen with hydrogen.
UR - https://www.scopus.com/pages/publications/0018069568
UR - https://www.scopus.com/pages/publications/0018069568#tab=citedBy
U2 - 10.1016/0003-2697(78)90752-2
DO - 10.1016/0003-2697(78)90752-2
M3 - Article
C2 - 707803
SN - 0003-2697
VL - 89
SP - 284
EP - 291
JO - Analytical Biochemistry
JF - Analytical Biochemistry
IS - 1
ER -