Abstract
Characteristic impedance, compliance, and resistance of a lumped model of the systemic arterial tree are identified in the time and frequency domains during control and during aortic occlusion. There is no significant difference in the parametric values obtained using either approach. The time-domain method, however, is both simple and fast and can afford the advantage of online identification.
| Original language | American English |
|---|---|
| Pages | 75-76 |
| Number of pages | 2 |
| State | Published - 1990 |
| Event | Proceedings of the Sixteenth Annual Northeast Bioengineering Conference - University Park, PA, USA Duration: Mar 26 1990 → Mar 27 1990 |
Other
| Other | Proceedings of the Sixteenth Annual Northeast Bioengineering Conference |
|---|---|
| City | University Park, PA, USA |
| Period | 3/26/90 → 3/27/90 |
ASJC Scopus subject areas
- General Chemical Engineering